• When my hot water is running, the central heating is getting warm - with Combi Boiler installed +
    • Please contact us as this will require a visit from an engineer.
  • My central heating isn't working but hot water is working +
    • Turn your thermostat to its maximum position and check if a C appears on the boiler display. If the boiler fires and the radiators come on, this means the room thermostat wasn't set higher than the room temperature.
    • If the boiler still doesn't fire, please contact us as this will require a visit from an engineer
  • Flashing D AND U Divertor valve in mid-position for service +
    • Rotate all knobs fully clockwise
    • Turn the boiler off
    • Turn the boiler back on and then press restart
  • Flashing L AND 4 Flow Thermistor +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code L4 as this will require a visit from an engineer.
  • Flashing L AND C: 5 Boiler Reset in 15 Minutes +
    • The boiler has been reset too many times in 15 minutes.
    • Turn the power to the boiler on and off again to reset
  • Flashing S AND E Service Interval Timer +
    • Please contact the installer
  • Flashing F AND A Flow & Return Reversed +
    • The flow and return differential is wrong and may have been installed correctly / possible crossed pipes.
    • Please contact the installer
  • Flashing F AND U Flow & Return Differential more than 50⁰ +
    • There difference between the water flow and return is too high (more than 50⁰)
    • Turn the boiler off and bleed/let out the air of your radiators. Ensure the boiler pressure is still at 1 to 1.5 BAR and turn the boiler back on. 
    • Possible blockage, please contact us quoting error code FU (we won't take offence) as this will require a visit from an engineer.

    View our video on how to top up your boiler pressure:

  • Flashing F AND D No Water Flow +
    • Turn the boiler off and bleed/let out the air of your radiators. Ensure the boiler pressure is still at 1 to 1.5 BAR and turn the boiler back on.
    • Your central heating pump may not be running. Gently touch it and if it's working properly, there should be a gentle vibration and it should also be warm
    • If you believe the central heating pump is NOT running, contact your installer.
    • If you believe the central heating pump is running, please contact us quoting error code FA as this will require a visit from an engineer.

    View our video on how to top up your boiler pressure:

  • Flashing C AND 0 BCC Activation Fault +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code C0 as this will require a visit from an engineer.
  • Flashing C AND 2 BCC Chip +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code C2 as this will require a visit from an engineer.
  • Flashing F AND 0 No Water Flow Thermistor +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code F0 as this will require a visit from an engineer.
  • Flashing F AND 7 Low Mains Volume +
    • Voltage to the boiler may be too low
    • Contact a local electrician to inspect the electrics of your property
  • Flashing F AND 6 Outside Sensor Fault +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code F6 as this will require a visit from an engineer.
  • Flashing F AND 5 Return Thermistor +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code F5 as this will require a visit from an engineer.
  • Flashing F AND 4 Flow Thermistor +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code F4 as this will require a visit from an engineer.
  • Flashing F AND 3 Fan Fault +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code F3 as this will require a visit from an engineer.
  • Flashing F AND 2 Flame Loss / Ignition Lockout +
    • Reset the boiler
    • If your gas meter is pay-as-you-go, check there is credit available
    • Check other gas powered items in your home, if these are also not working, you should contact a local gas engineer
    • Check that the yellow gas isolation valve under the boiler hasn't been turned off. If it is on, the handle/knob will be in pointing in the direction of the pipe.
    • If the boiler is making a gurgling/garglign noise whilst trying to fire, please contact your installer as there may be a blockage
    • If this does not fix the problem, call us quoting Error Code F2
  • Flashing F AND 1 Low Pressure +
    • Water pressure is too low in the system and will require topping up to between 1 and 1.5 BAR 

    View our video on how to top up your boiler pressure:

  • Flashing L AND 6 False Flame Lockout +
    • Reset the boiler
    • If this does not fix the problem, please contact us quoting error code L6 as this will require a visit from an engineer.
  • Flashing L AND 5 +
    • The boiler has been reset too many times in 15 minutes.
    • Turn the power to the boiler on and off again to reset
  • Flashing L AND 3 No Water Flow +
    • Check that the water pressure to the boiler is at 1 to 1.5 BAR.
    • Check that the yellow gas isolation valve under the boiler hasn't been turned off. If it is on, the handle/knob will be in pointing in the direction of the pipe
    • Turn the boiler off and bleed/let out the air of your radiatiors. Ensure the boiler pressur is still at 1 to 1.5 BAR and turn the boiler back on
    • Press the reset button
    • If this does not fix the problem, please contact us quoting error code L3

    View our video on how to top up your boiler pressure:

  • Flashing L AND 2 Flame Loss or Ignition Lockout +
    • Reset the boiler
    • If your gas meter is pay-as-you-go, check there is credit available
    • Check other gas powered items in your home, if these are also not working, you should contact a local gas engineer
    • Check that the yellow gas isolation valve under the boiler hasn't been turned off. If it is on, the handle/knob will be in pointing in the direction of the pipe.
    • If the boiler is making a gurgling/gargling noise whilst trying to fire, please contact your installer as there may be a blockage
    • If this does not fix the problem, call us quoting Error Code L2
  • Flashing L AND 1 Flow Temperature Overheat or No Water Flow +

    Ensure that all radiator valves are open Check that the water pressure to the boiler is at 1 to 1.5 BAR. View our video on how to top up your boiler pressure here.Reset the boilerIf this does not fix the problem, please contact us

    Learn more